Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Am J Clin Pathol ; 157(3): 345-352, 2022 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-34596224

RESUMO

OBJECTIVES: To summarize and assess the literature on the performances of methods beyond the Friedewald formula (FF) used in routine practice to determine low-density lipoprotein cholesterol (LDL-C). METHODS: A literature review was performed by searching the PubMed database. Many peer-reviewed articles were assessed. RESULTS: The examined methods included direct homogeneous LDL-C assays, the FF, mathematical equations derived from the FF, the Martin-Hopkins equation (MHE), and the Sampson equation. Direct homogeneous assays perform inconsistently across manufacturers and disease status, whereas most FF-derived methods exhibit variable levels of performance across populations. The MHE consistently outperforms the FF but cannot be applied in the setting of severe hypertriglyceridemia. The Sampson equation shows promise against both the FF and MHE, especially in severe hypertriglyceridemia, but data are still limited on its validation in various settings, including disease and therapeutic states. CONCLUSIONS: There is still no consensus on a universal best method to estimate LDL-C in routine practice. Further studies are needed to assess the performance of the Sampson equation.


Assuntos
Análise Química do Sangue , LDL-Colesterol , Análise Química do Sangue/normas , LDL-Colesterol/sangue , LDL-Colesterol/normas , Humanos , Triglicerídeos/sangue , Triglicerídeos/normas , Estudos de Validação como Assunto
2.
PLoS One ; 16(3): e0236772, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33740794

RESUMO

BACKGROUND: This is the first Egyptian nationwide study for derivation of reference intervals (RIs) for 34 major chemistry analytes. It was conducted as a part of the global initiative by the IFCC Committee on Reference Intervals and Decision Limits (C-RIDL) for establishing country-specific RIs based on a harmonized protocol. METHODS: 691 apparently healthy volunteers aged ≥18 years were recruited from multiple regions in Egypt. Serum specimens were analyzed in two centers. The harmonization and standardization of test results were achieved by measuring value-assigned serum panel provided by C-RIDL. The RIs were calculated by parametric method. Sources of variation of reference values (RVs) were evaluated by multiple regression analysis. The need for partitioning by sex, age, and region was judged primarily by standard deviation ratio (SDR). RESULTS: Gender-specific RIs were required for six analytes including total bilirubin (TBil), aspartate and alanine aminotransferase (AST, ALT). Seven analytes required age-partitioning including glucose and low-density lipoprotein cholesterol (LDL-C). Regional differences were observed between northern and southern Egypt for direct bilirubin, glucose, and high-density-lipoprotein cholesterol (HDL-C) with all their RVs lower in southern Egypt. Compared with other collaborating countries, the features of Egyptian RVs were lower HDL-C and TBil and higher TG and C-reactive protein. In addition, BMI showed weak association with most of nutritional markers. These features were shared with two other Middle Eastern countries: Saudi Arabia and Turkey. CONCLUSION: The standardized RIs established by this study can be used as common Egyptian RI, except for a few analytes that showed regional differences. Despite high prevalence of obesity among Egyptians, their RVs of nutritional markers are less sensitive to increased BMI, compared to other collaborating countries.


Assuntos
Bilirrubina/normas , Proteína C-Reativa/normas , HDL-Colesterol/normas , Testes de Química Clínica/normas , Adolescente , Adulto , Idoso , Bilirrubina/sangue , Biomarcadores/sangue , Índice de Massa Corporal , Proteína C-Reativa/análise , HDL-Colesterol/sangue , Egito , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Análise de Regressão , Triglicerídeos/sangue , Triglicerídeos/normas , Adulto Jovem
3.
Clín. investig. arterioscler. (Ed. impr.) ; 32(5): 209-218, sept.-oct. 2020. tab
Artigo em Espanhol | IBECS | ID: ibc-196745

RESUMO

En general, las guías de práctica clínica tanto europeas con americanas han abordado el control de la dislipidemia aterogénica de forma poco convincente e incluso superficial, en gran medida por las limitaciones terapéuticas disponibles. En consecuencia, esta dislipidemia está infradiagnosticada, infratratada e infracontrolada. Dada la reciente aparición de la guía 2019 de la European Atherosclerosis Society y de la European Society of Cardiology sobre el control de las dislipidemias, parece oportuno examinar su posicionamiento con respecto a la dislipidemia aterogénica y/o sus principales componentes, el aumento en las lipoproteínas ricas en triglicéridos y la disminución del colesterol de las lipoproteínas de alta densidad


In general, both European and American clinical guidelines have addressed the management of atherogenic dyslipidaemia in an unconvincing and even superficial way, largely because of the available therapeutic limitations. Consequently, this type of dyslipidaemia is underdiagnosed, under-treated, and under-controlled. Given the recent presentation of the 2019 guidelines of the European Atherosclerosis Society and the European Society of Cardiology on the management of dyslipidaemias, it seems appropriate to examine its position with respect to atherogenic dyslipidaemia and/or its main components, the increase in triglyceride-rich lipoproteins, and the decrease of high-density lipoprotein cholesterol


Assuntos
Humanos , Dislipidemias/prevenção & controle , Guias de Prática Clínica como Assunto/normas , Doenças Cardiovasculares/prevenção & controle , Triglicerídeos/normas , HDL-Colesterol/análise , Lipoproteínas HDL/normas , Apolipoproteínas B/normas , Aterosclerose/prevenção & controle , Hipolipemiantes/uso terapêutico , Hipertrigliceridemia/tratamento farmacológico , Hipertrigliceridemia/genética
4.
J Korean Med Sci ; 32(3): 427-433, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28145645

RESUMO

The aim of this study was to establish ethnic- and gender-specific cut-off values of triglycerides and glucose index (TyG index) for clinical usefulness in a representative sample of Mexican American, Non-Hispanic White, Non-Hispanic Black, and Korean adolescents. The data were collected from datasets of the National Health and Nutrition Examination Survey between 1999 and 2012, and the Korean National Health and Nutrition Examination Survey between 2005 and 2013. Receiver operating characteristic curve analysis was used to find valid cut-off values of the TyG index for metabolic syndrome. The total number of eligible participants was 3,164 in the US and 4,873 in Korea. The optimal cut-off value with the Cook et al. definition revealed 8.55 in Mexican American, 8.55 in Non-Hispanic White, 8.35 in Non-Hispanic Black, and 8.45 in Korean, respectively. The cut-off value with the de Ferranti et al. definition was 8.45, 8.45, 8.15, and 8.35, and the cut-off value with the International Diabetes Federation definition was 8.65, 8.65, 8.15, and 8.55, respectively. These findings may be clinically useful for evaluating insulin resistance for determining metabolic abnormalities in adolescents.


Assuntos
Glicemia/análise , Síndrome Metabólica/diagnóstico , Triglicerídeos/sangue , Adolescente , Negro ou Afro-Americano , Área Sob a Curva , Povo Asiático , HDL-Colesterol/sangue , Feminino , Humanos , Resistência à Insulina , Masculino , Americanos Mexicanos , Inquéritos Nutricionais , Curva ROC , Valores de Referência , República da Coreia , Triglicerídeos/normas , Estados Unidos , População Branca
5.
Chem Phys Lipids ; 189: 7-18, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26004846

RESUMO

Knowledge of the plasma lipid composition is essential to clarify the specific roles of different lipid species in various pathophysiological processes. In this study, we developed an analytical strategy combining high-performance liquid chromatography with evaporative light scattering detection (HPLC-ELSD) and off-line coupling with matrix-assisted laser desorption/ionization with time-of-flight mass spectrometry (MALDI-TOF/MS) to determine the composition of plasma and major lipoproteins at two levels, lipid classes and lipid species. We confirmed the suitability of MALDI-TOF/MS as a quantitative measurement tool studying the linearity and repeatability for triglycerides (TG), phosphatidylethanolamine (PE) and phosphatidylcholine (PC). Moreover, data obtained with this method were correlated with other lipid classes and species measurements using currently available technologies. To establish the potential utility of our approach, human plasma very low density- (VLDL), low density- (LDL) and high density- (HDL) lipoproteins from 10 healthy donors were separated using ultracentrifugation, and compositions of nine lipid classes, cholesteryl esters (CE), TG, free cholesterol (FC), PE, phosphatidylinositol (PI), sulfatides (S), PC, lysophosphatidylcholine (LPC) and sphingomyelin (SM), analyzed. In total, 157 lipid species in plasma, 182 in LDL, 171 in HDL, and 148 in VLDL were quantified. The lipidomic profile was consistent with known differences in lipid classes, but also revealed unexpected differences in lipid species distribution of lipoproteins, particularly for LPC and SM. In summary, the methodology developed in this study constitutes a valid approach to determine the lipidomic composition of plasma and lipoproteins.


Assuntos
Lipídeos/sangue , Lipoproteínas/sangue , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Cromatografia Líquida de Alta Pressão , Feminino , Humanos , Lipídeos/isolamento & purificação , Lipoproteínas/isolamento & purificação , Fosfatidilcolinas/sangue , Fosfatidilcolinas/normas , Fosfatidiletanolaminas/sangue , Fosfatidiletanolaminas/normas , Extração em Fase Sólida , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/normas , Triglicerídeos/sangue , Triglicerídeos/normas
6.
J Korean Med Sci ; 27(12): 1530-5, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23255853

RESUMO

The aims of this study were to investigate the validity of Friedewald's formula and to propose a range of triglyceride values over which the formula can be used without significant error. This was a cross-sectional analysis of 1,929 subjects (946 males and 983 females) aged 20 yr and older using data of the Korea National Health and Nutrition Examination Survey in 2009. Estimated total number was considered to be 10,633,655 (5,846,384 males and 4,787,271 females). Calculated and directly-measured low density lipoprotein cholesterol (LDL-C) values were highly correlated (r = 0.96); however, significant differences were observed between the directly-measured and calculated LDL-C concentrations. Subjects in the underestimated group (10.5%) had higher dysmetabolic profiles than those in the overestimated group (11.4%). Although serum triglyceride level showed the greatest independent association with differences between the calculated and directly-measured LDL-C concentrations, no statistically significant differences were noted when triglyceride concentration was between 36 and 298 mg/dL (93.2%). In conclusion, Friedewald's formula accurately estimates directly-measured serum LDL-C concentration in Korean adults. However, the formula can be applied to subjects with serum triglyceride concentrations from 36 to 298 mg/dL without significant error.


Assuntos
LDL-Colesterol/sangue , Triglicerídeos/sangue , Adulto , Povo Asiático , Índice de Massa Corporal , LDL-Colesterol/normas , Estudos Transversais , Feminino , Humanos , Hiperlipidemias/diagnóstico , Masculino , Pessoa de Meia-Idade , Inquéritos Nutricionais , Valores de Referência , Análise de Regressão , República da Coreia , Triglicerídeos/normas
7.
Anal Chim Acta ; 722: 80-6, 2012 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-22444537

RESUMO

The kinetic method was applied to differentiate and quantify mixtures of regioisomeric triacylglycerols (TAGs) by generating and mass selecting alkali ion bound metal dimeric clusters with a TAG chosen as reference (ref) and examining their competitive dissociations in a quadrupole ion trap mass spectrometer. This methodology readily distinguished pairs of regioisomers (AAB/ABA) such as LLO/LOL, OOP/OPO and SSP/SPS and consequently distinguished sn-1/sn-3, sn-2 substituents on the glycerol backbone. The dimeric complex ions [ref, Li, TAG((AAB and/or ABA))](+) generated by electrospray ionization mass spectrometry were subjected to collision induced dissociation causing competitive loss of either the neutral TAG reference (ref) leading to [Li(AAB and/or ABA)](+) or the neutral TAG molecule (TAG((AAB and/or ABA))) leading to [ref, Li](+). The ratio of the two competitive dissociation rates, defined by the product ion branching ratio (R(iso)), was related via the kinetic method to the regioisomeric composition of the investigated TAG mixture. In this work, a linear correlation was established between composition of the mixture of each TAG regioisomer and the logarithm of the branching ratio for competitive fragmentation. Depending on the availability of at least one TAG regioisomer as standard, the kinetic method and the standard additions method led to the quantitative analysis of natural TAG mixtures.


Assuntos
Espectrometria de Massas por Ionização por Electrospray , Triglicerídeos/análise , Cinética , Óleos Voláteis/química , Padrões de Referência , Espectrometria de Massas por Ionização por Electrospray/normas , Estereoisomerismo , Termodinâmica , Triglicerídeos/normas
8.
Talanta ; 85(1): 177-82, 2011 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-21645687

RESUMO

The present work studies the effectiveness of the use of triacylglycerols (TAGs) for the quantification of olive oil in blends with vegetable oils. The determinations were obtained using high-performance liquid chromatography (HPLC) coupled to a Charged Aerosol Detector (CAD), in combination with Partial Least Squares (PLS) regression and using interval PLS (iPLS) for variable selection. Results revealed that PLS models can predict olive oil concentrations with reasonable errors. Variable selection through iPLS did not improve predictions significantly, but revealed the chemical information important in the chromatogram to quantify olive oil in vegetable oil blends.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Óleos de Plantas/análise , Triglicerídeos/normas , Análise dos Mínimos Quadrados , Métodos , Azeite de Oliva
9.
Spine (Phila Pa 1976) ; 36(11): E699-704, 2011 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-21289585

RESUMO

STUDY DESIGN: A calcium triglyceride bone cement (CTBC) was compared with the gold-standard polymethylmethacrylate (PMMA) to assess the stability of augmented sacral screw fixation under cyclic loading. OBJECTIVE: To determine whether CTBC augmentation of a pedicle screw would provide a similar level of fixation in the S1 pedicles compared with PMMA augmentation. SUMMARY OF BACKGROUND DATA: Numerous studies have shown the advantages of using PMMA to augment screw fixation; however, its biomechanical properties are not ideal. CTBC offers potential benefits such as being low exothermic, a modulus of elasticity closer to bone, and the potential for osteoconductivity, but its comparative performance in this situation has not been previously evaluated. METHODS: Six cadaveric sacra were used in this study; 3.0 mL volumes of PMMA (Simplex P) and CTBC (Kryptonite™ Bone Cement) were injected into contralateral screw tracts, with the screw immediately inserted after cement injection. After a 12-hour setting period, the sacrum was potted in a custom fixture and mounted to the frame of a materials testing machine. Alternating flexion and extension bending moments were applied at 1 Hz. Flexion moments were applied starting at 0.5 Nm and increased by 1 Nm after every 1000 cycles until the screw had reached 6° of rotation relative to its starting position. Extension moments were maintained at 0.5 Nm. Screw rotation relative to bone was determined in real time by a custom optical tracking system and was analyzed using two-way repeated-measures analyses of variance (ANOVAs) and post hoc Student-Newman-Keuls tests (α = 0.05). RESULTS: To reach 6° of screw rotation, the PMMA-augmented screw required more loading cycles (15,464 ± 2526 vs. 10,277 ± 1762 cycles; P = 0.006) and a larger applied moment (15.3 ± 2.2 vs. 10.5 ± 1.7 Nm; P = 0.010) than CTBC-augmented screw. CONCLUSION: The PMMA augmentation provided increased resistance to cyclic loading compared with the CTBC augmentation for sacral pedicle screw fixation, but both augmentations well exceeded previously published findings for nonaugmented screws.


Assuntos
Cimentos Ósseos , Parafusos Ósseos/efeitos adversos , Compostos de Cálcio , Polimetil Metacrilato , Falha de Prótese/efeitos adversos , Sacro/cirurgia , Fusão Vertebral/instrumentação , Triglicerídeos , Idoso , Idoso de 80 Anos ou mais , Cimentos Ósseos/efeitos adversos , Cimentos Ósseos/química , Cimentos Ósseos/normas , Parafusos Ósseos/normas , Cadáver , Compostos de Cálcio/efeitos adversos , Compostos de Cálcio/química , Compostos de Cálcio/normas , Humanos , Pessoa de Meia-Idade , Polimetil Metacrilato/efeitos adversos , Polimetil Metacrilato/química , Polimetil Metacrilato/normas , Sacro/fisiologia , Fusão Vertebral/efeitos adversos , Fusão Vertebral/métodos , Triglicerídeos/efeitos adversos , Triglicerídeos/química , Triglicerídeos/normas
10.
Curr Atheroscler Rep ; 13(1): 12-22, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21107758

RESUMO

The latest recommended goals for blood lipid levels may require multiple lipid drugs. Lower doses in combination may render more efficacy and safety than highest doses of single agents. Except for isolated hypoalphalipoproteinemia (a low level of high-density lipoprotein cholesterol), therapies will start with a statin. All marketed statins are acceptable. The choice may be based on dose- efficacy and patient's tolerability. High-potency statins (eg, atorvastatin, simvastatin, or rosuvastatin) are often chosen. Currently, generic statins, such as simvastatin, lovastatin, pravastatin, and fluvastatin, offer cost benefits. The choice of added agent depends on the "residual lipoprotein abnormalities" after statin therapy, efficacy, compliance issues, and cost. Approved "combined" preparations improve cost and compliance. To further lower low-density lipoprotein cholesterol, ezetimibe is a safe, efficacious choice, pending resolution of a controversial trial's results. Colesevelam is moderately effective and the best tolerated bile acids sequestrant. In combined dyslipidemias, extended-release niacin is the best tolerated niacin preparation; other quality-controlled immediate-release preparations have similar safety and efficacy but produce more flushing of the skin. Niacin or fenofibrate is effective in normalizing high-density lipoprotein and triglyceride levels persisting after statin therapy. Agents approved by the US Food and Drug Administration and the latest guidelines of the National Cholesterol Education Program, American Heart Association/American College of Cardiology provide choices and indications of drug combinations.


Assuntos
Doença da Artéria Coronariana/prevenção & controle , Quimioterapia Combinada/normas , Dislipidemias/tratamento farmacológico , Hipolipemiantes , LDL-Colesterol/sangue , LDL-Colesterol/normas , Ensaios Clínicos Controlados como Assunto , Doença da Artéria Coronariana/etiologia , Custos de Medicamentos , Monitoramento de Medicamentos , Sinergismo Farmacológico , Quimioterapia Combinada/economia , Medicamentos Genéricos , Dislipidemias/complicações , Ácidos Graxos Ômega-3/administração & dosagem , Ácidos Graxos Ômega-3/efeitos adversos , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/administração & dosagem , Inibidores de Hidroximetilglutaril-CoA Redutases/efeitos adversos , Hipolipemiantes/administração & dosagem , Hipolipemiantes/efeitos adversos , Assistência de Longa Duração , Dose Máxima Tolerável , Guias de Prática Clínica como Assunto , Triglicerídeos/sangue , Triglicerídeos/normas
11.
Clin Chim Acta ; 397(1-2): 55-9, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18687321

RESUMO

BACKGROUND: An uncontrolled systematic error in serum biomarkers may be a serious problem when comparing their trends both within and between populations. The aim of the study was to assess which factors are responsible for systematic errors in the measurement of serum triglycerides (Tg) and the effect of fasting on serum triglycerides in Finnish population surveys. METHODS: Data on precision and accuracy during 30 years for serum triglycerides were documented from participation in 492 rounds of five different external quality assessment (EQA) programs. Data on fasting and health status from questionnaires were combined from three population surveys comprising 27,131 participants. RESULTS: The mean annual accuracy (bias) of the Tg methods from all EQAs during 1978-2007 was -1.54% (95% CI -2.25, -0.83). The mean relative change in triglyceride concentration per fasting hour was -3.7% (95% CI -4.2, -3.1) in all subjects. A minimum serum Tg concentration was seen in men and women who had fasted for at least 8 and 7 h, respectively. CONCLUSIONS: The mean bias in serum Tg analyses has been very small throughout the 30-year period. Fasting has a considerable effect on triglyceride levels, but they can be converted either to fasting or non-fasting levels using specific factors.


Assuntos
Doenças Cardiovasculares/sangue , Doenças Cardiovasculares/epidemiologia , Jejum/sangue , Triglicerídeos/sangue , Triglicerídeos/normas , Erros de Diagnóstico , Feminino , Finlândia/epidemiologia , Humanos , Masculino , Fatores de Risco , Inquéritos e Questionários
12.
Ann Clin Biochem ; 45(Pt 3): 260-5, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18482913

RESUMO

BACKGROUND: Targets for cholesterol reduction are part of the Quality Outcomes Framework and general practitioners have to meet these targets to fulfil their remuneration package. By contrast, there are no targets for the accuracy of cholesterol or other lipid measurements and no recent surveys on performance of these assays. We have assessed the performance of lipid measurement of the available methods in the UK. METHODS: Serum samples collected from individual donors attending the national blood service were distributed after values were obtained from a secondary reference laboratory. Samples were sent to participant laboratories to assess different methods' analytical performance on single donation specimens, on routine external quality assessment pooled specimens, on specimens subjected to a range of freeze-thaw cycles and on frozen-stored specimens. RESULTS: Differences in measured cholesterol were found that were method-dependent and related to triglyceride content. HDL-cholesterol (HDL-C) showed significant positive bias in all assays. Individual donor specimens showed no significant changes with differing numbers of freeze-thaw cycles. Pooled serum was stable for up to six months. CONCLUSIONS: Most cholesterol measurements are accurate but some methods are affected by triglyceride interference. HDL-C methods show significant positive bias. Although there are potential matrix effects introduced as a result of specimen preparation, additional work is needed to show if these effects are present in fresh patient samples.


Assuntos
Lipídeos/sangue , Calibragem , Colesterol/análise , Colesterol/normas , HDL-Colesterol/análise , HDL-Colesterol/normas , Humanos , Lipídeos/normas , Garantia da Qualidade dos Cuidados de Saúde , Controle de Qualidade , Padrões de Referência , Valores de Referência , Reprodutibilidade dos Testes , Triglicerídeos/análise , Triglicerídeos/normas
13.
Circulation ; 117(1): 32-42, 2008 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-18071074

RESUMO

BACKGROUND: New age- and sex-specific lipoprotein cut points developed from National Health and Nutrition Examination Survey (NHANES) data are considered to be a more accurate classification of a high-risk lipoprotein level in adolescents compared with existing cut points established by the National Cholesterol Education Program (NCEP). The aim of this study was to determine which of the NHANES or NCEP adolescent lipoprotein classifications was most effective for predicting abnormal levels in adulthood. METHODS AND RESULTS: Adolescent and adult measures of total cholesterol, low-density lipoprotein cholesterol, high-density lipoprotein cholesterol, and triglycerides were collected in 365 Australian, 1185 Finnish, and 273 US subjects participating in 3 population-based prospective cohort studies. Lipoprotein variables in adolescence were classified according to NCEP and NHANES cut points and compared for their ability to predict abnormal levels in adulthood. With the use of diagnostic performance statistics (sensitivity, specificity, positive predictive value, negative predictive value, area under receiver operating characteristic curve) in pooled and cohort-stratified data, the NHANES cut points (compared with NCEP cut points) were more strongly predictive of low high-density lipoprotein cholesterol in adults but less predictive of high total cholesterol, high low-density lipoprotein cholesterol, and high triglyceride levels in adults. We identified heterogeneity in the relative usefulness of each classification between cohorts. CONCLUSIONS: The separate use of NHANES cut points for high-density lipoprotein cholesterol and NCEP cut points for total cholesterol, low-density lipoprotein cholesterol, and triglycerides yielded the most accurate classification of adolescents who developed dyslipidemia in adulthood.


Assuntos
Dislipidemias/classificação , Lipoproteínas/sangue , Valor Preditivo dos Testes , Adolescente , Adulto , Fatores Etários , Austrália/epidemiologia , Criança , HDL-Colesterol/sangue , HDL-Colesterol/normas , LDL-Colesterol/sangue , LDL-Colesterol/normas , Classificação , Dislipidemias/diagnóstico , Dislipidemias/epidemiologia , Feminino , Finlândia/epidemiologia , Humanos , Lipoproteínas/normas , Masculino , Fatores Sexuais , Triglicerídeos/sangue , Triglicerídeos/normas , Estados Unidos/epidemiologia
14.
Clin Lab ; 48(11-12): 635-46, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12465749

RESUMO

This article describes the process of "repairing" a method which has gone out of control, using the gas-chromatographic isotope-dilution mass spectrometric (GC-IDMS) determination of total glycerides in serum, measured as glycerol. The original method used 13C2-glycerol as aqueous internal standard and 12C-tripalmitin dissolved in toluene as external standard. The modified method used tripalmitin as internal and external standard, the former being labelled uniformly on the glycerol moiety of tripalmitin (13C3-tripalmitin). In addition, glycerol-free human serum albumin was added to the external standards to "trap" the glycerol physically during evaporation of the extraction solvent after alkaline hydrolysis. The modified method was more stable than the original one and the intensity of the MS-signal in the modified method was at least 100 times stronger in the external standards than in the original method. The precision of the modified method in measuring total glycerides in serum samples (as total glycerol) was better than in the original method, the coefficients of variation being under 1.5% at concentrations between 0.8 and 3.5 mmol/l.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Triglicerídeos/análise , Radioisótopos de Carbono , Humanos , Padrões de Referência , Projetos de Pesquisa , Albumina Sérica , Triglicerídeos/normas
15.
Bioorg Med Chem ; 9(2): 245-54, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11249117

RESUMO

Some cationic triglycerides 1Aa-1Cb which have a symmetrical structure were effectively synthesized and formulated into cationic liposomes with the co-lipid dioleoylphosphatidylethanolamine (DOPE) and/or dilauroylphosphatidylcholine (DLPC). The plasmid encoding a luciferase was delivered into CHO cells by using these cationic liposomes. Our symmetrical cationic triglycerides showed high transfection activity when DOPE was used as a co-lipid. Among the symmetrical cationic triglycerides synthesized here, 1Ab and 1Ac, which have an oleoyl group at the 1- and 3-position in the glycerol backbone and also have a relatively long linker connecting the 2-hydroxy group in glycerol with the quaternary ammonium head group, were found to be the most suitable for gene delivery into cells. The transfection activity of the symmetrical cationic triglyceride 1Ab was comparable with that of its asymmetrical congener 6 and several times higher than that of Lipofectin.


Assuntos
Técnicas de Transferência de Genes/normas , Lipossomos/síntese química , Triglicerídeos/síntese química , Animais , Cátions , Humanos , Lipossomos/normas , Lipossomos/uso terapêutico , Luciferases/genética , Espectroscopia de Ressonância Magnética , Fosfatidiletanolaminas , Fosfolipídeos/metabolismo , Triglicerídeos/metabolismo , Triglicerídeos/normas
16.
Clin Biochem ; 33(1): 15-24, 2000 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10693982

RESUMO

OBJECTIVE: To implement a quality control program for the standardization and harmonization of lipid and lipoprotein analyses as performed at two core laboratories (St. Paul's Hospital, UBC [Vancouver], and NPHI [Helsinki]) for the Diabetes Atherosclerosis Intervention Study (DAIS). DESIGN AND METHODS: A DAISSOFT computer program was designed to minimize the occurrence of data and sample management errors during the course of the study. Fresh human serum was used for the provision of an accuracy based external quality control program that monitored the analytical performance of lipid testing at these two laboratories. A separate program was designed for monitoring hemoglobin A1c (HbA1c). At the outset of the study, allowable total error goals were established for each analyte. Ongoing performance was monitored using bimonthly blinded challenges of fresh human serum. The two EQA programs routinely monitored the analysis of total cholesterol, calculated LDL-cholesterol, HDL-cholesterol, net triglycerides, apoprotein A-1, apoprotein B, and HbA1c. RESULTS: The EQA precision and accuracy data for the measurement of total cholesterol at the two core laboratories over the last 5 years indicated both laboratories operated with good precision, approximately 1% CV over the time period. The accuracy at both laboratories was similar initially. Part way through the study, the accuracy of the cholesterol method at NHPI tended to drift upward with an operating positive bias (+3%) relative to the Abell Kendall reference method. Triglyceride measurements were the most problematic for the study. By EQA cycle 8, the accuracy of the method at UBC had stabilized and was meeting the accuracy goals of the study. NPHI's method was negatively biased relative to the accuracy base of the DAIS study. In spite of recalibrating their method, NPHI found it difficult to maintain consistent accuracy for the measurement of triglycerides during the study. Both laboratories operated their HDL methods with excellent precision. Accuracy at NHPI was well maintained over the course of the study whereas the accuracy of HDL measurements at UBC was more problematic. There was an inconsistent variation in the accuracy of apoprotein A-1 measurements at both laboratories. In most cases, the bias would be corrected by the time of the next EQA challenge. In the case of apo B, one laboratory was standardized to the CDC while the other laboratory was standardized to IFCC/WHO. The discrepancy between these two accuracy bases was >20%. Recalibration to a common accuracy base rectified the problem. Only minor problems were encountered with the precision and accuracy of the DIAMAT assay for hemoglobin A-1c. The two DAIS core laboratories consistently operated within the 9% total error goals of the study for HbA1c. CONCLUSIONS: Through the use of this program, the two DAIS core laboratories were able to maintain their lipid analyses within the limits of allowable total error that had been established for the study.


Assuntos
Testes de Química Clínica/normas , Lipídeos/normas , Lipoproteínas/normas , Apolipoproteína A-I/análise , Apolipoproteína A-I/normas , Apolipoproteínas B/análise , Apolipoproteínas B/normas , Colesterol/análise , Colesterol/normas , HDL-Colesterol/análise , HDL-Colesterol/normas , Método Duplo-Cego , Hemoglobinas Glicadas/análise , Hemoglobinas Glicadas/normas , Humanos , Lipídeos/análise , Lipoproteínas/análise , Garantia da Qualidade dos Cuidados de Saúde/normas , Controle de Qualidade , Padrões de Referência , Valores de Referência , Reprodutibilidade dos Testes , Triglicerídeos/análise , Triglicerídeos/normas
19.
J Toxicol Sci ; 22(1): 25-44, 1997 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9076655

RESUMO

A control survey was conducted to check the accuracy of automated analyzers used in the evaluation of clinical chemistry parameters in nonclinical toxicology studies. Pooled serum samples from male Sprague-Dawley rats were delivered refrigerated to each facility 98 laboratory facilities throughout Japan within 18 hours after sample preparation and analyzed. Commercially available normal human serum samples from a single lot were also analyzed at the same time. Survey results were divided into three categories. (1) Parameters with small coefficient of variation (CV) values for both rat and human serum samples included protein, glucose, cholesterol (CHO), urea nitrogen (UN), sodium (Na), potassium (K), chloride (Cl), calcium (Ca), and inorganic phosphate (IP). Definition of normal values in rats should be straight forward for these parameters. (2) Parameters with large CV values, but with a relatively good correlation between rat and human values include triglycerides (TG), glutamic oxaloacetic transaminase/aspartate aminotransferase (GOT/AST), glutamic pyruvic transaminase/alanine aminotransferase (GPT/ALT), and alkaline phosphatase (ALP). Measurements based on different principles gave different mean values, and this values contributed to the increase in CV values. Assessment of normal values would require a consideration of the measurement principles. (3) Parameters with large CV values only in rat serum samples included albumin (albumin/globulin ratio: A/G ratio), creatinine (CRE), and total bilirubin(BIL). Reactivity was different in rat albumin (ALB), depending on the reagents used. This difference needs to be corrected with values available by electrophoresis, or adjusted by rat ALB values, because of the lack of an appropriate measurement method. The enzyme method gave low values for rat CRE, which suggests the need for further examination of this method. The BIL values were extremely low in rat samples. It seems to be necessary to select appropriate methods to measure clinical pathology parameters correctly for rats. There was no deviation in values due solely to the mechanical operations of the analytical equipment. Non-standard initial settings of the equipment (equipment originally intended for human samples, but now applied to animal samples) was the main cause of the wide range of analytical values seen.


Assuntos
Análise Química do Sangue/normas , Albuminas/normas , Animais , Bilirrubina/normas , Análise Química do Sangue/instrumentação , Análise Química do Sangue/métodos , Glicemia/análise , Proteínas Sanguíneas/normas , Nitrogênio da Ureia Sanguínea , Colesterol/normas , Creatinina/normas , Eletrólitos/normas , Globulinas/normas , Humanos , Japão , Masculino , Fosfatos/normas , Controle de Qualidade , Ratos , Ratos Sprague-Dawley , Triglicerídeos/normas
20.
Lipids ; 31(12): 1311-22, 1996 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-8972466

RESUMO

Triacylglycerols of the seed oils rich in alpha- and/or gamma-linolenic acid moieties were separated by silver-ion high-performance liquid chromatography (HPLC) followed by on-line atmospheric pressure chemical ionization-mass spectrometric (APCI-MS) detection. Mass spectra of most triacylglycerols exhibited abundant [M + H]+ and [M - RCO2]+ ions, which defined the molecular weight and the molecular association of fatty acyl residues of a triacylglycerol, respectively. Silver ions formed weaker complexes with triacylglycerols containing gamma-linolenic acid than with those containing alpha-linolenic acid, i.e., the elution order of molecules was XYT gamma > XYT alpha, XT gamma T gamma > XT gamma T alpha > XT alpha T alpha, and T gamma T gamma T gamma > T gamma T gamma T alpha > T gamma T alpha T alpha > T alpha T alpha T alpha, where T alpha = alpha-linolenic acid, T gamma = gamma-linolenic acid, and X, Y = fatty acids different from linolenic acid. Furthermore, silver-ion HPLC resulted in partial separation within equally unsaturated triacylglycerols according to differences in the combined number of acyl carbons. Regioisomeric forms of triacylglycerols were not determined from the seed oil samples, although differences were measured with reference compounds in the relative abundances of [M - RCO2]+ ions formed by a loss of a fatty acyl residue from the sn-2 position and the sn-1/3 positions. Silver-ion HPLC/APCI-MS provided valuable information for structure elucidation of seed oil triacylglycerols: 43 molecular species were identified from cloudberry seed oil, 39 from evening primrose oil, 79 from borage oil, 44 from alpine currant, and 56 from black currant seed oils. The quantitation requires to be studied further, especially in those cases where several molecular weight species of triacylglycerols eluted in a single chromatographic peak.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas/métodos , Triglicerídeos/análise , Cromatografia Líquida de Alta Pressão/normas , Ácidos Graxos/análise , Ácidos Graxos/química , Ácidos Graxos/normas , Espectrometria de Massas/normas , Estrutura Molecular , Óleos de Plantas/química , Padrões de Referência , Sementes/química , Prata , Triglicerídeos/química , Triglicerídeos/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...